Home
About
Company Profile
Enterprise Culture
Technical Team
Qualification Certificate
Patent Certificate
Partners
Products
Gauss meter
Fluxmeter
Hard Magnetic Materials
Magnetic Field Scanner
Soft Magnetic Materials
Magnetic Field Series
Helpful Accessories
Magnetic Moment
Application
Service Support
Business Process
After-sale Service
Video Column
Cases
News
Company Dynamics
Magnetic Knowledge
Marketing Activities
Thesis Highlights
Contact
Contact Number
Online Message
Magnetic knowledge
Marketing activities
Space magnetic field distribution measuring instrument case sharing
The FE-2100RD spatial magnetic field distribution measuring instrument can test the spatial magnetic field distribution, and provide XY coordinates, P polar coordinates, 3D magnetic field distribution and harmonic analysis relative to the fundamental wave and other testing methods. It meets the quality inspection of permanent magnet, permanent magnet motor stator or rotor, DC magnetic field coil, electromagnet and other quality inspection for magnetic products in domestic and foreign markets. The following is the spatial magnetic field distribution measuring instrument case sharing:
29
2020
/
05
Silicon steel sheet iron loss meter measuring principle and use precautions
The silicon steel sheet iron loss meter is a special instrument for measuring the iron loss of silicon steel sheet. It can be displayed directly through the digital meter head and can intuitively understand the loss of electrical steel sheet. The instrument is mainly used for on-site detection of iron loss value of single silicon steel sheet. Can be widely used in silicon steel sheet production, trade, motors, transformers and other applications of silicon steel sheet manufacturing products industry for silicon steel sheet quality management
14
Main features and software functions of iron loss meter
The silicon steel sheet iron loss meter is widely used in the quality management of silicon steel sheet manufacturers, sales manufacturers, motors and transformers, etc. It is mainly used in the inspection of silicon steel sheet incoming materials, processing monitoring and other production links, with simple and convenient operation.
FE-30SST silicon steel sheet iron loss measuring instrument panel introduction and operation instructions
The FE-30SSTLOSSMETER silicon steel sheet iron loss measuring instrument of Hunan Yongyi Technology Co., Ltd. is quite different from similar products on the market at present. The single machine is equipped with a calibrated magneticometer to meet the measurement of oriented and non-oriented monolithic silicon steel, and to meet the more accurate measurement of the mass loss Ps and magnetic induction Bm of silicon steel sheet. Can be equipped with the upper computer software, can be B- H hysteresis loop, u-H permeability curve and Ps-B loss curve measurement, under certain circumstances, to meet the alternative square ring standard test silicon steel strip sample of the full performance parameters.
20
04
Measurement method of H-coil magnetometer for soft magnetic materials measuring open strip bar
According to the shape of the soft magnetic material sample, the two measurement methods of closed circuit magnetic ring and open circuit strip rod can be divided into open circuit solenoid method and H coil magnetometer method. The following is the H-coil magnetometer measurement method for soft magnetic materials to measure open strip rods:
07
Soft magnetic materials-Method of measurement for open-circuit strip bar solenoids
According to the shape of the soft magnetic material sample, the two measurement methods of closed circuit magnetic ring and open circuit strip rod can be divided into open circuit solenoid method and H coil magnetometer method. The following is the soft magnetic material open strip bar solenoid measurement method:
02
Measurement of soft magnetic materials-Methods of measurement of closed-circuit magnetic rings
According to the shape of the soft magnetic material sample, the two measurement methods of closed circuit magnetic ring and open circuit strip rod can be divided into open circuit solenoid method and H coil magnetometer method. The following is the measurement method of closed-circuit magnetic ring for soft magnetic material measurement:
31
03
Analysis of nondestructive testing of permanent magnet materials using the pole head embedded coil method
Using the electromagnet pole surface embedded coil method to test the permanent magnet material is an application-oriented technical scheme designed according to the BH characteristics of the current industrial test permanent magnet material. Since the actual size and shape of the sample do not need to be considered during the test, there is no need to wind or set a fixed B/J coil on the magnet, and only the test sample needs to be completely covered on a coil embedded in the pole head, the test is convenient, The repeatability is good, and there is a certain market prospect.
25