FE-103 desktop gauss meter instructions


FE-103 desktop gaussmeter has ac and dc measurement, peak hold, north and south pole judgment and other functions. It can be used for the inspection of AC/DC magnetic field and the inspection of magnetic field peak, the inspection of AC/DC magnetic field distribution, the inspection of permanent magnet magnetizing condition, the inspection of magnetic field distribution in AC/DC coil, the inspection of gap magnetic field of AC/DC electromagnet, and the inspection of regular AC/DC magnetic field.

  FE-103 table gaussmeterProduct Introduction
   FE-103 table gaussmeterIt can be used to measure the magnetic induction of AC and DC magnetic fields. The instrument range is wide, easy to operate, perfect quality assurance, high-quality after-sales service, is the ideal choice for your work.
   GaussiometerIt is a special instrument for detecting magnetic induction intensity, and it is one of the most widely used measuring instruments in the field of magnetic measurement.
FE-103 Gaussmeter based on the Hall effect magnetic field strength measurement instrument, using high stability constant current source circuit technology design and manufacture of a desktop gaussmeter. The test probe adopts imported GaAs linear Hall chip, the difference between the probes is very small, and the user can directly replace the damage. It is an ideal AC/DC magnetic field test instrument. The instrument has AC and DC measurement, peak hold, north and south pole judgment and other functions. It can be used for the inspection of AC/DC magnetic field and the inspection of magnetic field peak, the inspection of AC/DC magnetic field distribution, the inspection of permanent magnet magnetizing condition, the inspection of magnetic field distribution in AC/DC coil, the inspection of gap magnetic field of AC/DC electromagnet, and the inspection of regular AC/DC magnetic field.
  FE-103 table gaussmeterApplication Work Area
Measurement of magnetic induction intensity of various magnetic fields such as AC and DC magnetic fields.
The magnetic field distribution on the surface or space of the permanent magnetic material (that is, we usually call the measurement table magnetic);
Gap magnetic field in magnetic circuit structure;
The magnetic field generated by permanent magnet or AC and DC current acts on the magnetic field generated by the equipment used to absorb ferromagnetic materials (e. g.: iron separator, magnetic separator, magnetic chuck, electromagnet, demagnetizer);
  FE-103 table gaussmeterAppearance description
FE-103 Desktop Gaussmeter Front Panel
1. Header Display Window
2. Zero adjustment knob
3. Display calibration coefficient (when the light is on)
4. Peak hold (when the light is on)
5. AC/DC selection (AC when the light is on)
6. Range selection
7. Probe interface
8. Power switch
  FE-103 table gaussmeterRear Panel
1. Analog output interface 2. Power socket
  FE-103 table gaussmeterMain technical indicators
1. Range: 0 ~ 200mT ~ 2000mT
2. Accuracy: 1.0%(corresponding to full scale of each gear)
3. Resolution: 0.1Gs
4. Measured magnetic field: AC/DC magnetic field measurement
5. Function description: peak hold function When measuring static magnetic field, the N and S poles can be judged by the and-numbers in the number of passes. Adjust ADJ zero setting
6. Ambient temperature: 5 ℃ ~ 40 ℃
7. Relative humidity: 20% ~ 80% (no condensation)
8. Power supply: 220V 50HZ
9. Exterior dimensions: 250mm(L)× 180mm(W)× 90mm(H)
10. Instrument weight: 2Kg
11. Display mode: 4 1/2 LCD
12. Display unit: Gs/mT
  FE-103 table gaussmeterOperating steps for use
1 Connect the power cord;
2 Install the sensor. Insert the hall sender plug into the probe connection hole on the front panel of the instrument.
3 Press the POWER button on the panel.
4 Instrument parameter adjustment
According to the measured magnetic field, press the "Gs/mT" function key to select the appropriate range zero, select AC measurement and DC measurement according to the measured magnetic field, and press the "AC/DC" function key to switch (AC when the light is on). If the gauge reading is not zero, adjust the ADJ knob to set the reading to zero. After zeroing, it can be measured normally. Note: If the measurement range needs to be converted, it must be reset to zero, and then re-measured;
5 Measurements
Open the Hall sensor sheath, and then make the effective position of the Hall sensor (horizontal sensor) or (longitudinal sensor) closely contact the surface of the measured material (DC magnetic field) or the position of the measured magnetic field to measure, and the value displayed on the meter is the measured The size of the magnetic field.
6 Peak hold
If it is necessary to lock the maximum value in the measurement process, press the "HOLD" button to make the light on, and the measurement meter head will display the maximum value measured in the measurement process. In the measurement process of the peak hold measurement state, if the peak value needs to be measured again, and this peak value is expected to be smaller than the original peak value, it is necessary to press the "HOLD" key again and then reset the zero measurement. Because when the instrument enters the peak hold state, there must be a value greater than the existing display value before the data display changes. If the measured data is smaller than the existing display value, the display value will not change. Therefore, it must be reset according to the peak value at this time. Note: The Peak Measurement status is still in this case. Note: After the instrument is tested, insert the sheath on the sensor.
GaussiometerUnit conversion 0.1mT = 1Gs 1T = 10000Gs
  FE-103 table gaussmeterProduct appearance
 
  FE-103 table gaussmeterEquipment Packing List
FE-103 table gaussmeter 1
Standard Hall probe 1
Product description 1 copy
1 power cord
Note: The specific delivery list shall prevail.