The FE-2100MQ rare earth permanent magnet material quality test device uses a fluxmeter and Helmholtz coil to test the quality of rare earth materials has become the most popular inspection method among enterprises. Although the magnetic properties of the test materials are not as accurate as the permanent magnet material BH measurement device , Can not provide the intrinsic coercive force Hcj parameters of the material, but because the test magnetic moment data is more reliable, the equipment cost is lower, and it is suitable for transmission and communication between all material manufacturing and users. It will be used in the field of magnetic measurement in the future. Play a bigger role.
没有此类产品
Product Details
technical parameter
Test case
measurement principle
FE-2100MQ rare earth permanent magnet material quality testing device uses fluxmeter and Helmholtz coil testing the quality of rare earth materials has become the most popular among enterprises Inspection method, although the magnetic performance of the test material is not as accurate as the permanent magnetic material BH measuring device, and the intrinsic coercivity Hcj parameter of the material cannot be provided, but the test magnetic moment data is more reliable, the equipment cost is lower, and it is suitable for all materials manufacturing Communication and communication with users will play a greater role in the field of magnetic measurement in the future.
 
Product introduction
FE-2100MQ rare earth permanent magnet material quality test device uses fluxmeter With configuration one-dimensional Helmhol This coil, it is mainly applied to the permanent magnet device under the condition of the coil For magnetic flux measurement, multiply the coil constant to obtain the magnetic moment of the device. For samples of regular size, the materials Br, Hcb, and BHmax can be calculated. Experiments have verified that the use of one-dimensional coils to test axially magnetized cylindrical, toroidal, and square-type rare earth permanent magnet samples can accurately test the total magnetic moment M (to be precise, Mz) of the material, and the material BH demagnetization curve is close to The straight line can accurately calculate the three important parameters of the magnetic properties of the material, Br, Hcb, and BHmax, so as to judge the quality of the material. It is well used for the transfer of the quality of rare earth permanent magnet materials between material companies and material users. Among them, the accuracy and repeatability of the magnetic moment test are far superior to the use of BH test equipment to test standard samples to transmit data. The high test efficiency can achieve full inspection of all magnetized samples, and timely discover device defects, while ensuring that the materials Judgement of magnetic energy product level.  
Corresponding parameter set not found, please add it in property template of background
Technical indicators
● Power supply: AC 220V/0.5A
● Test range: 1mWb, 10 mWb, 100 mWb, 1000 mWb four gears
● Corresponding input impedance: 1k ohm, 10k ohm, 100k ohm, 1000k ohm
● Test accuracy: 0.5%
● Drift: 1uWb/minute
● Minimum resolution: 0.1uWb (corresponding to 2mwb range)
● Volume: 285mm×300mm×100mm, weight: 3kg; (width * depth * height)
● Operating environment: 0℃ to +50℃, humidity: 35~80%.

 

1. SmCo28H sample size: L20mm× W10mm× 5mm, the test data using FE-2100H permanent magnet material measuring device is as follows: Br=10.83kGs, Hcb=10.26kOe, Hcj≥30kOe, BHmax=27.78MGOe.
Using FE-2100MQ rare earth permanent magnet material quality test device with one-dimensional Helmholtz coil (urec is calculated at 1.05):

Number

M(uWbm)

Ø(mWb)

Br(T)

Hcb(kOe)

BHmax(MGOe)

1

1.059

2.659

1.088

10.08

27.42

2

1.059

2.659

1.088

10.08

27.41

3

1.059

2.66

1.088

10.09

27.43

4

1.06

2.663

1.089

10.1

27.49

5

1.059

2.661

1.088

10.09

27.45

6

1.059

2.661

1.088

10.09

27.45

7

1.06

2.663

1.089

10.1

27.49

8

1.059

2.661

1.088

10.09

27.44

9

1.059

2.66

1.088

10.09

27.43

10

1.06

2.662

1.089

10.09

27.47

Average

1.0593

2.6609

1.0883

10.09

27.448

Maximum value

1.06

2.663

1.089

10.1

27.49

Minimum

1.059

2.659

1.088

10.08

27.41

Positive deviation%

0.066

0.0789

0.0643

0.0991

0.1530

Negative deviation%

-0.028

-0.0714

-0.0276

-0.0991

-0.1384

The test repeatability is excellent. The difference between Br test accuracy and the BH test device is controlled within 0.6%. The permeability coefficient is calculated at 1.05 (accurate optimization can be performed), the Hcb deviation is within 1.56%, and the BH deviation is 1.04%.
 
2. N30M sample size: D13.08mm× H6.35mm, the test data using FE-2100H permanent magnet material measuring device are as follows: Br=11.06kGs, Hcb=10.68kOe, BHmax=29.53MGOe.
Using FE-2100MQ rare earth permanent magnet material quality test device with one-dimensional Helmholtz coil (urec is calculated at 1.05):

Number

M(uWbm)

Ø(mWb)

Br(T)

Hcb(kOe)

BHmax(MGOe)

1

0.9232

2.319

1.105

10.52

29.06

2

0.923

2.318

1.105

10.52

29.05

3

0.9227

2.318

1.104

10.52

29.03

4

0.9226

2.317

1.104

10.52

29.02

5

0.9227

2.318

1.104

10.52

29.03

6

0.9226

2.317

1.104

10.52

29.02

7

0.9223

2.317

1.104

10.51

29.01

8

0.9221

2.316

1.104

10.51

28.99

9

0.9216

2.315

1.103

10.5

28.96

10

0.9216

2.315

1.103

10.5

28.96

Average

0.92244

2.317

1.104

10.514

29.013

Maximum value

0.9232

2.319

1.105

10.52

29.06

Minimum

0.9216

2.315

1.103

10.5

28.96

Positive deviation%

0.0824

0.08632

0.09058

0.0572

0.1620

Negative deviation%

-0.0914

-0.0863

-0.09058

-0.1332

-0.1827

The test repeatability is excellent, the Br test accuracy is 0.2% compared with the BH test device, and the permeability coefficient is calculated at 1.05 (accurate optimization), the Hcb deviation is within 1.55%, and the BH deviation is 1.75%.
暂未实现,敬请期待
暂未实现,敬请期待